High Pressure Filter
FK series

Product specification
-
Unidirectional oil flow or constant displacement oil pump applications
-
Oil viscosity at 32 cSt, absolute filtration accuracy of 10 microns, flow rate up to 280 l/min
-
Maximum operating pressure 350 Bar. Burst pressure above 1050 Bar
-
Effective absolute filtration up to 3 micron 99.5% removal rate (βx≧200)
-
Complies with ISO international standards for filter design and manufacturing
Filter differential pressure curve (empty cylinder) – 0.9 specific gravity of oil
-
The differential pressure of the filter (empty cylinder) and the differential pressure of the bypass valve directly correspond to the specific gravity of the fluid and increase or decrease in proportion to the difference
Filter differential pressure parameter
-
AA/AB/AC/AD-superior service life and removal rate of 99.5% or more at 3, 5, 10 and 20 microns. The filter material uses inert inorganic fibers by Polyester non-woven fabric heat bonding fixed fibers to achieve high filtration efficiency Maintenance; and the use of EPOXY two-liquid epoxy resin combined with the entire filter element to achieve its burst strength (20 bar) and leak-free integrity. The upstream and downstream of the folded wave filter media are supported by a steel mesh to achieve the resistance required by the frequency flow change during cold start (20 bar)
Filter differential pressure calculation
Calculate and define the actual differential pressure value using the filter according to the filter data parameters provided above
Filter set ΔP = filter cartridge ΔP + filter cartridge ΔP
The flow rate and differential pressure curve of the filter cartridge are selected according to the parameter table of the flow rate and differential pressure of the filter element
Use the flow rate to correspond to the differential pressure value, and then use the flow rate and the oil product according to the parameters of the oil filter.
The specific gravity of the product and the test oil are proportional to the specific gravity and oil viscosity to calculate the filter differential pressure
Calculate the differential pressure of the filter cartridge ΔP = flow rate × filter element differential pressure parameter × oil ratio
Filter cartridge ΔP = ΔP × oil specific gravity ÷ 0.9 weight ÷ 0.9 × oil viscosity ÷ 32
Filter group ΔP = 1.15 × 0.88 ÷ 0.9 + 90 × 0.0076 × 0.88 ÷ 0.9 × 46 ÷ 32
Example: 10um filter accuracy
SK12T08NACYEN10S** = 1.12 + 0.96
Flow rate = 90 LPM
Oil viscosity = 46 cSt = 2.08 bar
Specific gravity of oil = 0.88
Explanation of differential pressure calculation recommendations
Pro-Pure's filter element corresponds to a high amount of pollutant, and Pro-Pure recommends that the differential pressure calculation of the filter group (when the filter element is still clean under the flow rate and oil operation) is the filter group differential pressure value ΔP 0.3× ≦ Set value of differential pressure indicator is appropriate
Cartridge specifications
Material: Filter seat-carbon steel
Filter Barrel-Carbon Steel
Pressure rating: The recommended maximum operating pressure is 250 kg/cm2 (3625 psig)
Test burst pressure 1050 kg/cm2 (15225 psig)
By-pass valve setting: By-pass valve setting value is as the above-mentioned bypass valve flow and differential pressure curve
Temperature grade: Buna-N seal (-40°C~107°C); Viton-V seal (-29°C~125°C)
Import and export: 12T-3/4"PT; 16T-1"PT; 20T-11/4"PT
Filter specifications
Hardware components: anti-corrosion electroplated clean end caps and center support
Filter material: Inert inorganic fiber (micro glass fiber), which is assembled and fixed by EPOXY epoxy resin.
Cleanable all-metal filter elements are also available.
Fluid chemical compatibility: Compared with petroleum base oil, water glycol, emulsified oil and HWCF with Buna-N seals
Claim. Viton-V seals are matched with phosphate ester oil and are tested according to ISO 2943.
Burst differential pressure rating: AA/AB/AC/AD – 20 bar
The above-mentioned breakdown pressure level is based on the ISO 2941 standard.
Differential pressure indicator
Type: visual or electronic
Output display mode: red/blue-please replace if contaminated/cleaning is still normal (visual type)
NO Normally Open / NC Normally Closed-Telecommunications Contact (Electronic)
Body material: aluminum alloy 6061-T6
Miniature switch specifications: 2 amps at 220VAC, 28VDC (resistive)
1 amps at 220VAC, 28VDC (inductive)
Electronic wiring method: DIN 43650 connection connector
Filter options
Filter group P/N: FK
Box 1: 12T -3/4"; 16T -1"; 20T -11/4" PT pipe thread installation specifications (PF teeth are available)
Box 2 : 04, 08 -FK12&16; 07, 10 -F K20 filter element length
Box 3: N -Nitrile; V -Fluorine rubber seal
Box 4: AA -3um; AB -5um; AC -10um; AD -20um filter accuracy
Box 5: A -3.5 bar bypass; B -10 bar bypass; R -counterflow; N -without valve device
Box 6: A -2.5 bar visual; B -2.5 bar electronic; D -7 bar visual; E -7 bar electronic differential pressure indicator
Box 7: N -None; B -Other configuration with drain hole at the bottom of the cylinder
Box 8:10 - 12T & 16T; 20 - 20T Design No.
Note: When R or N is selected for Box 5 , please select high-destruction filter element. For filter element parameters, please contact Chunjing
Filter element P/N:
Box 1: E -Replacement filter
Box 2 : A -Filter element type
Box 3: AA -3um; AB -5um; AC -10um; AD -20um filter element filtering accuracy
Box 4: 04, 08 for FK12&16; 07, 10 for FK20 filter length
Box 5: N -Nitrile ; V -Fluorine rubber seal
Note: 022047 is for FK12; 026055 is for FK16; 034069 is for FK20