top of page

    High Pressure Filter

    FF03 series

    Product specification

    • Flow rate 60/110 LPM at 10 microns absolute filtration / 32Cst

    • Maximum operating pressure is 3625 psig. Burst pressure above 15000 psig

    • Effective absolute filtration up to 3 microns 99.5% removal rate

    • Complies with ISO international standards for filter design and manufacturing

    Filter differential pressure curve (empty cylinder) – 0.9 specific gravity of oil

    ◆ – FF03

    The differential pressure of the filter (empty cylinder) and the differential pressure of the bypass valve directly correspond to the specific gravity of the fluid and increase or decrease in proportion to the difference

    Filter differential pressure parameter

    • AA/AB/AC/AD-superior service life and removal rate of 99.5% or more at 3, 5, 10 and 20 microns. The filter material uses inert inorganic fibers by Polyester non-woven fabric heat bonding fixed fibers to achieve high filtration efficiency Maintenance; and the use of EPOXY two-liquid epoxy resin combined with the entire filter element to achieve its burst strength (300psid) and leak-free integrity. The upstream and downstream of the folded wave filter media are supplemented by a steel mesh support to achieve the resistance (300 psid) required for the frequency flow change during cold activation.

    • AE/AF/AG/AH-used to protect the forced filtration required by the servo valve and proportional valve (without bypass valve design), its burst pressure reaches 3000 psid. To provide full-time filtering protection.

    Filter differential pressure calculation

    Calculate and define the actual differential pressure value using the filter according to the filter data parameters provided above

     

    Filter set ΔP = filter cartridge ΔP + filter cartridge ΔP

    The flow rate and differential pressure curve of the filter cartridge are selected according to the parameter table of the flow rate and differential pressure of the filter element

    Use the flow rate to correspond to the differential pressure value, and then use the flow rate and the oil product according to the parameters of the oil filter.

    The specific gravity of the product and the test oil are proportional to the specific gravity and oil viscosity to calculate the filter differential pressure

    Calculate the differential pressure of the filter cartridge ΔP = parameter × oil specific gravity ÷ 0.9 × oil viscosity

    Filter cartridge ΔP = ΔP × oil specific gravity ÷ 0.9 ÷ 150 SUS (or × oil viscosity ÷ 32cSt)

     

    Filter group ΔP = 16 × 0.88 ÷ 0.9 + 90 × 0.11 × 0.88 ÷ 0.9 × 200 ÷ 150

     

    example:

    FF0308NACBEN10 = 15.6 psid + 12.9 psid
    Flow rate = 90 LPM
    Oil viscosity = 200SUS = 28.5 psid
    Specific gravity of oil = 0.88

     

    Explanation of differential pressure calculation recommendations

    Pro-Pure's filter element corresponds to a high amount of pollutant dirt, Pro-Pure recommends the calculation of the differential pressure of the filter group (when the filter element is still clean under the flow rate and oil operation) is the differential pressure value of the filter group is ΔP= 0.3× differential pressure indicator setting value (100 psid)

    Installation options

    Differential pressure indicator

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Optional board-mounted high-pressure filter

     

     

     

    Filter group P/N: FF

    Box 1: 03 board connection installation specifications

    Box 2 : 04, 08 filter element length

    Box 3: N -Buna; V -Viton; E -EPR seal

    Box 4: AC -filter element breakdown and filter accuracy grade, see filter element differential pressure parameter table for details

    Box 5: A -50 psid bypass; B -150 psid bypass; R -reversible flow; N -without valve device

    Box 6: A -35 psid visual; B -35 psid electronic; D- 100 psid visual; E -100 psid electronic differential pressure indicator

    Box 7: N -No accessories Other configurations

    Box 8 : 10-Design Number

    Filter element P/N:

    Box 1: E -Replacement filter

    Box 2 : A -Filter element type

    Box 3: AC -filter element breakdown and filter accuracy grade, see filter element differential pressure parameter table for details

    Box 4: 04; 08 -filter element length

    Box 5: N -Buna; V -Viton; E -EPR seal

    Screenshot 2020-05-25 at 7.24.31 PM.png
    Screenshot 2020-05-25 at 7.26.41 PM.png
    Screenshot 2020-05-27 at 1.52.03 PM.png
    Screenshot 2020-05-27 at 2.04.34 PM.png
    Screenshot 2020-05-27 at 2.08.13 PM.png
    Screenshot 2020-05-25 at 5.06.04 PM.jpg
    Screenshot 2020-05-25 at 5.06.04 PM.jpg

    Visual or electronic

    Type:

    3000 psig

    Maximum operating pressure:

    -43°C to 105°C

    Temperature class:

    35 & 100 psid

    Differential pressure setting:

    Auto reset

    Reset mode:

    The red/blue for is contaminated, please replace/clean it is still normal. (Visual type)

    Reed switch NO normally open for cleaning is still normal / closed circuit is contaminated, please replace. (Electronic)

    Output display mode:

    NBR or Viton

    Seals:

    Aluminum alloy 6061-T6

    Body material:

    Installation method:

    The differential pressure indicator is suitable for PROPURE filters, which are installed at the differential pressure teeth of the filter. Can also be installed on another differential pressure circuit board

    Electronic switch form:

    NC/NO normally open/closed contacts with DIN connector.

    Electronic reed switch specifications:

    1 amps at 220VAC, 28VDC(resistive)
    0.5 amps at 220VAC, 28VDC(inductive)

    Pro-Pure filter cartridges are recommended for use in non-bypass forced filtration systems. This is suitable for the application of servo valves or proportional valves, and also allows the reverse flow device to provide load relief or feedback

    Screenshot 2020-05-25 at 7.46.41 PM.png

    The selection of bypass valve is suitable for various application needs. According to the ANSI 12.2.6 standard, the filter element of the filter group must not be damaged under all the differential pressure conditions of the filter operation; based on the integrity of the filter element without damage, a bypass device can be set. Generally speaking, the higher the bypass setting value, the greater the differential pressure range of the filter element and the longer the service life.

    Screenshot 2020-05-25 at 7.46.52 PM.png

    Contact Us

    Thanks for submitting!

    Unit C, 11/F, Block 1, Kinho Industrial Building, 14-24 Au Pui Wan Street, Fo Tan, Sha Tin, New Territories, Hong Kong

    Phone: 2116 3878

    WeChat: 147 1430  3100

    © 2020 by Pro-Pure HK.

    淳靖香港 reg.  trade mark.bmp

    ®

    bottom of page